| TELEMAG |
|

TELEMAG
The Telemag line of telescopic lifting columns features the best combination
of minimum retracted height and large stroke length. Telemag is available in DC
and AC and three phase current. (Exclude specifications, data available in technical
data sheet) |
|

KOM -
Control Units
The line of Telemag actuators is complimented by the KOM control units, which
allow a flexible and more application focused system control. KOM control units
are ideal to handle low-voltage control for simple tasks or microprocessor technology
for complex control solutions. |
|

Applications
Telemag telescopic columns are used wherever robust and safe guiding systems
are needed to lift medical equipment of furniture. The attractive design allows
the Telemag to often become part of the overall design of the equipment or furniture.
|
|
|
|
|
How does it work?
The Telemag telescopic columns are extremely reliable and solid square aluminum
stands with an inner and outer tube. They are available in 2 section as well as
3 section versions for increased offset load capabilities. The inner tube is telescoped
and retracted with great force and high accuracy by the built-in electrical drive.
Telemag actuators run very quiet and are maintenance free. They are complimented
by a large number of control solutions, operating elements and other accessories.
Various support heights, different load capacities and stroke lengths are also
available. The different control solutions allow memory operation, parallel running
and single operation of up to 5 drives (24 VDC only). Please refer to the data
sheets 530D and 2935 for more information on combination of different drives and
operating elements. The large number of available combinations opens the way for
new solutions in rehabilitation and workplace ergonomics.
|
|
| |
|
| Technical
data |
24 V DC |
120/230V DC |
|
|
| Pushforce
max. |
2500
N |
2500
N |
|
|
| Speed |
15 - 19
mm/sec. |
15 - 19
mm/sec. |
|
|
| Stroke |
200-400
mm |
200-400
mm |
|
|
| Retracted
height |
S + 130 mm |
S + 130 mm |
|
|
| Telescopic
column version |
3-
section |
3-
section |
|
|
| Voltage |
24 V DC |
120/230
V DC |
|
|
| Current
consumption |
5
A |
1.8/1
A |
|
|
Duty
cycle:
Intermittent operation |
int.
1 min./
9 min. |
int.
1 min./
9 min. |
|
|
Duty
cycle:
Short-time operation |
3 min. |
3 min. |
|
|
| Ambient
temperature |
+10
/ +40 °C |
+10
/ +40 °C |
|
|
| Protection class |
IP
30 |
IP
30 |
|
|
| Isolation class |
SELV |
I |
|
|
| Weight
|
8-13 kg |
8-13 kg |
|
|
| Datasheet
(PDF) |
Datasheet TFG10/50/90 |
|
| Further Information |
Operating Manual Telemag |
|
|
 |
| |
TELEMAG
TGC8A...
(Voltage 230
VAC / separate switch over contact and operating elements) |
| Technical
data |
TGC8AWAS |
TGC8AWAK |
TGC8AWDS |
TGC8AWDK |
| Pushforce
max. |
1000
N |
1000
N |
1000
N |
1000
N |
| Speed |
9
mm/sec. |
9
mm/sec. |
9
mm/sec. |
9
mm/sec. |
| Stroke |
200-700
mm |
200-700
mm |
300-700
mm |
300-700
mm |
| Retracted
height |
345-845
mm |
345-845
mm |
345-745
mm |
345-745
mm |
| Telescopic
column version |
2-
section |
2-
section |
3-
section |
3-
section |
| Voltage |
230
V/50 Hz |
230
V/50 Hz |
230
V/50 Hz |
230
V/50 Hz |
| Power
consumption |
210
W |
210
W |
210
W |
210
W |
| Current
consumption |
0.95
A |
0.95
A |
0.95
A |
0.95
A |
Duty
cycle:
Intermittent operation |
int.
1 min./
19 min. |
int.
1 min./
19 min. |
int.
1 min./
19 min. |
int.
1 min./
19 min. |
Duty
cycle:
Short-time operation |
KB
2 min. |
KB
2 min. |
KB
2 min. |
KB
2 min. |
| Ambient
temperature |
+10
/ +40 °C |
+10
/ +40 °C |
+10
/ +40 °C |
+10
/ +40 °C |
| Degree
of protection |
IP
30 |
IP
30 |
IP
30 |
IP
30 |
| Type
of control |
electrical |
pneumatic |
electrical |
pneumatic |
| Weight
|
4.5
- 7.5 kg |
4.5
- 7.5 kg |
5.9
- 9.5 kg |
5.9
- 9.5 kg |
| Datasheet
(PDF) |
Datasheet TGC8A... |
|
|
| Further Information |
Operating Manual Telemag |
|
|
 |
| |
TELEMAG
THC8A...
(Voltage 230
VAC / separate switch over contact and operating elements) |
| Technical
data |
THC8AWAS |
THC8AWAK |
THC8AWDS |
THC8AWDK |
| Pushforce
max. |
1800
N |
1800
N |
1800
N |
1800
N |
| Speed |
12
mm/sec. |
12
mm/sec. |
12
mm/sec. |
12
mm/sec. |
| Stroke |
200-700
mm |
200-700
mm |
230-700
mm |
230-700
mm |
| Retracted
height |
355-855
mm |
355-855
mm |
290-760
mm |
290-760
mm |
| Telescopic
column version |
2-
section |
2-
section |
3-
section |
3-
section |
| Voltage |
230
V/50 Hz |
230
V/50 Hz |
230
V/50 Hz |
230
V/50 Hz |
| Power
consumption |
500
W |
500
W |
500
W |
500
W |
| Current
consumption |
2.2
A |
2.2
A |
2.2
A |
2.2
A |
Duty
cycle:
Intermittent operation |
int.
1 min./
27 min. |
int.
1 min./
27 min. |
int.
1 min./
27 min. |
int.
1 min./
27 min. |
Duty
cycle:
Short-time operation |
KB
2 min. |
KB
2 min. |
KB
2 min. |
KB
2 min. |
| Ambient
temperature |
+10
/ +40 °C |
+10
/ +40 °C |
+10
/ +40 °C |
+10
/ +40 °C |
| Degree
of protection |
IP
30 |
IP
30 |
IP
30 |
IP
30 |
| Type
of control |
electrical |
pneumatic |
electrical |
pneumatic |
| Weight
|
7.9
- 13.5 kg |
7.9
- 13.5 kg |
8.6
- 17.5 kg |
8.6
- 17.5 kg |
| Datasheet
(PDF) |
Datasheet THC8A... |
|
|
| Further Information |
Operating Manual Telemag |
|
|
 |
| |
TELEMAG
TLC12 Z...
(Voltage 230
VAC / separate switch over contact and operating elements) |
| Technical
data |
TLC12ZWAS |
TLC12ZWAK |
TLC12ZWDS |
TLC12ZWDK |
| Pushforce
max. |
4000
N |
4000
N |
4000
N |
4000
N |
| Speed |
11
mm/sec. |
11
mm/sec. |
11
mm/sec. |
11
mm/sec. |
| Stroke |
200-700
mm |
200-700
mm |
255-700
mm |
255-700
mm |
| Retracted
height |
375-875
mm |
375-875
mm |
315-760
mm |
315-760
mm |
| Telescopic
column version |
2-
section |
2-
section |
3-
section |
3-
section |
| Voltage |
230
V/50 Hz |
230
V/50 Hz |
230
V/50 Hz |
230
V/50 Hz |
| Power
consumption |
890
W |
890
W |
890
W |
890
W |
| Current
consumption |
4.1
A |
4.1
A |
4.1
A |
4.1
A |
Duty
cycle:
Intermittent operation |
int.
1 min./
37 min. |
int.
1 min./
37 min. |
int.
1 min./
37 min. |
int.
1 min./
37 min. |
Duty
cycle:
Short-time operation |
KB
2 min. |
KB
2 min. |
KB
2 min. |
KB
2 min. |
| Ambient
temperature |
+10
/ +40 °C |
+10
/ +40 °C |
+10
/ +40 °C |
+10
/ +40 °C |
| Degree
of protection |
IP
30 |
IP
30 |
IP
30 |
IP
30 |
| Type
of control |
electrical |
pneumatic |
electrical |
pneumatic |
| Weight
|
15.2
- 24.5 kg |
15.2
- 24.5 kg |
18.3
- 30.5 kg |
18.3
- 30.5 kg |
| Datasheet
(PDF) |
Datasheet TLC12 Z... |
|
|
| Further Information |
Operating Manual Telemag |
|
|
 |
| |
TELEMAG
THG.B/C...
(Voltage 24
VDC with separate control unit and operating elements) |
| Technical
data |
THG1.-B |
THG1.-C |
|
|
| Pushforce
max. |
2000
N |
1000
N |
|
|
| Speed |
5.5
mm/sec. |
12
mm/sec. |
|
|
| Stroke |
200-700
mm |
200-700
mm |
|
|
| Retracted
height 2- section |
470-970
mm |
470-970
mm |
|
|
| Retracted
height 3- section |
380-880
mm |
380-880
mm |
|
|
| Voltage |
24
VDC |
24
VDC |
|
|
Current
consumption
|
5
A |
5
A |
|
|
Duty
cycle:
Intermittent operation |
int.
1 min./
9 min. |
int.
1 min./
9 min. |
|
|
Duty
cycle:
Short-time operation |
KB
2.5 min. |
KB
2.5 min. |
|
|
| Ambient
temperature |
+10
/ +40 °C |
+10
/ +40 °C |
|
|
| Degree
of protection |
IP
30 |
IP
30 |
|
|
| Weight
|
8
- 14 kg |
8
- 14 kg |
|
|
| Design
of telescopic column |
2
or 3 section |
2
or 3 section |
|
|
| Datasheet
(PDF) |
Datasheet THG.B/C... |
|
|
| Further Information |
Operating Manual Telemag |
|
|
 |
| |
TELEMAG
TLG.A/B/C...
(Voltage 24
VDC with separate control unit and operating elements) |
| Technical
data |
TLG1.-A |
TLG1.-B |
TLG1.-C |
|
| Pushforce
max. |
4000
N |
2500
N |
1500
N |
|
| Speed |
10
mm/sec. |
13
mm/sec. |
25
mm/sec. |
|
| Stroke |
200-700
mm |
200-700
mm |
200-700
mm |
|
| Retracted
height 2 section |
380-880
mm |
380-880
mm |
380-880
mm |
|
| Retracted
height 3 section |
380-880
mm |
380-880
mm |
380-880
mm |
|
| Voltage |
24
VDC |
24
VDC |
24
VDC |
|
| Current
consumption |
6.5
A |
6.5
A |
6.5
A |
|
Duty
cycle:
Intermittent operation |
int.
1 min./
9 min. |
int.
1 min./
9 min. |
int.
1 min./
9 min. |
|
Duty
cycle:
Short-time operation |
KB
2.5 min. |
KB
2.5 min. |
KB
2.5 min. |
|
| Ambient
temperature |
+10
/ +40 °C |
+10
/ +40 °C |
+10
/ +40 °C |
|
| Degree
of protection |
IP
30 |
IP
30 |
IP
30 |
|
| Weight
|
15
- 30 kg |
15
- 30 kg |
15
- 30 kg |
|
| Design
of telescopic column |
2
or 3 section |
2
or 3 section |
2
or 3 section |
|
| Datasheet
(PDF) |
Datasheet TLG.A/B/C... |
|
|
| Further Information |
Operating Manual Telemag |
|
|
 |
| |
TELEMAG TLT
(Voltage 24
VDC with separate control unit and operating elements) |
| Technical
data |
TLT10-C1 |
TLT10-B1 |
TLT10-C2 |
TLT10-A1 |
TLT10-A2* |
| Pushforce
max. |
1000
N |
2000
N |
2000
N |
3000
N |
4000
N |
| Speed |
25-36
mm/s |
13-19
mm/s |
25-42
mm/s |
11-16
mm/s |
13-19
mm/s |
| Stroke |
300-700
mm |
300-700
mm |
300-700
mm |
300-700
mm |
300-700
mm |
| Retracted
length |
320-520
mm |
320-520
mm |
320-590
mm |
320-520
mm |
390-590
mm |
| Telescopic
column version |
3-section |
3-section |
3-section |
3-section |
3-section |
| Voltage |
24
V DC |
24
V DC |
24
V DC |
24
V DC |
24
V DC |
| Current
consumption |
2x4
A |
2x4
A |
2x4,5
A |
2x3,5
A |
2x3,5
A |
Duty
cycle:
Intermittent operation |
int.
1 min./ 9 min. |
int.
1 min./ 9 min. |
int.
1 min./ 9 min. |
int.
1 min./ 9 min. |
int.
1 min./ 9 min. |
Duty
cycle:
Short-time operation |
KB
2,5 min. |
KB
2,5 min. |
KB
2,5 min. |
KB
2,5 min. |
KB
2,5 min. |
| Ambient
temperature |
+10
- +40°C |
+10
- +40°C |
+10
- +40°C |
+10
- +40°C |
+10
- +40°C |
| Degree
of protection |
IP
40 |
IP
40 |
IP
40 |
IP
40 |
IP
40 |
| Weight |
15
- 30 kg |
15
- 30 kg |
15
- 30 kg |
15
- 30 kg |
15
- 30 kg |
*
A2 units have a three times static safety
factor for strokes 600 and 700 mm. |
| Datasheet
(PDF) |
Datasheet TLT |
| Further Information |
Operating Manual Telemag |
 |
|