TELEMAG
 
 
 
 
 
 
 
TELEMAG
TFG10/50/90TGC8A  THC8A  TLC12Z
THG B/CTLG A/B/C TLT


TELEMAG
The Telemag line of telescopic lifting columns features the best combination of minimum retracted height and large stroke length. Telemag is available in DC and AC and three phase current. (Exclude specifications, data available in technical data sheet)


KOM - Control Units
The line of Telemag actuators is complimented by the KOM control units, which allow a flexible and more application focused system control. KOM control units are ideal to handle low-voltage control for simple tasks or microprocessor technology for complex control solutions.

 

Applications
Telemag telescopic columns are used wherever robust and safe guiding systems are needed to lift medical equipment of furniture. The attractive design allows the Telemag to often become part of the overall design of the equipment or furniture.
 

How does it work?
The Telemag telescopic columns are extremely reliable and solid square aluminum stands with an inner and outer tube. They are available in 2 section as well as 3 section versions for increased offset load capabilities. The inner tube is telescoped and retracted with great force and high accuracy by the built-in electrical drive. Telemag actuators run very quiet and are maintenance free. They are complimented by a large number of control solutions, operating elements and other accessories. Various support heights, different load capacities and stroke lengths are also available. The different control solutions allow memory operation, parallel running and single operation of up to 5 drives (24 VDC only). Please refer to the data sheets 530D and 2935 for more information on combination of different drives and operating elements. The large number of available combinations opens the way for new solutions in rehabilitation and workplace ergonomics.

 
 
   
NEW  TELEMAG TFG10/50/90
Technical data 24 V DC 120/230V DC    
Pushforce max. 2500 N 2500 N    
Speed 15 - 19 mm/sec. 15 - 19 mm/sec.    
Stroke 200-400 mm 200-400 mm    
Retracted height S + 130 mm S + 130 mm    
Telescopic column version 3- section 3- section    
Voltage 24 V DC 120/230 V DC    
Current consumption 5 A 1.8/1 A    
Duty cycle:
Intermittent operation
int. 1 min./
9 min.
int. 1 min./
9 min.
   
Duty cycle:
Short-time operation
 
3 min. 3 min.    
Ambient temperature +10 / +40 °C +10 / +40 °C    
Protection class IP 30 IP 30    
Isolation class SELV I    
Weight 8-13 kg 8-13 kg    
Datasheet (PDF) Datasheet TFG10/50/90
Further Information Operating Manual Telemag
  TELEMAG TGC8A...
(Voltage 230 VAC / separate switch over contact and operating elements)
Technical data TGC8AWAS TGC8AWAK TGC8AWDS TGC8AWDK
Pushforce max. 1000 N 1000 N 1000 N 1000 N
Speed 9 mm/sec. 9 mm/sec. 9 mm/sec. 9 mm/sec.
Stroke 200-700 mm 200-700 mm 300-700 mm 300-700 mm
Retracted height 345-845 mm 345-845 mm 345-745 mm 345-745 mm
Telescopic column version 2- section 2- section 3- section 3- section
Voltage 230 V/50 Hz 230 V/50 Hz 230 V/50 Hz 230 V/50 Hz
Power consumption 210 W 210 W 210 W 210 W
Current consumption 0.95 A 0.95 A 0.95 A 0.95 A
Duty cycle:
Intermittent operation
int. 1 min./
19 min.
int. 1 min./
19 min.
int. 1 min./
19 min.
int. 1 min./
19 min.
Duty cycle:
Short-time operation
 
KB 2 min. KB 2 min. KB 2 min. KB 2 min.
Ambient temperature +10 / +40 °C +10 / +40 °C +10 / +40 °C +10 / +40 °C
Degree of protection IP 30 IP 30 IP 30 IP 30
Type of control electrical pneumatic electrical pneumatic
Weight 4.5 - 7.5 kg 4.5 - 7.5 kg 5.9 - 9.5 kg 5.9 - 9.5 kg
Datasheet (PDF) Datasheet TGC8A...
Further Information Operating Manual Telemag
  TELEMAG THC8A...
(Voltage 230 VAC / separate switch over contact and operating elements)
Technical data THC8AWAS THC8AWAK THC8AWDS THC8AWDK
Pushforce max. 1800 N 1800 N 1800 N 1800 N
Speed 12 mm/sec. 12 mm/sec. 12 mm/sec. 12 mm/sec.
Stroke 200-700 mm 200-700 mm 230-700 mm 230-700 mm
Retracted height 355-855 mm 355-855 mm 290-760 mm 290-760 mm
Telescopic column version 2- section 2- section 3- section 3- section
Voltage 230 V/50 Hz 230 V/50 Hz 230 V/50 Hz 230 V/50 Hz
Power consumption 500 W 500 W 500 W 500 W
Current consumption 2.2 A 2.2 A 2.2 A 2.2 A
Duty cycle:
Intermittent operation
int. 1 min./
27 min.
int. 1 min./
27 min.
int. 1 min./
27 min.
int. 1 min./
27 min.
Duty cycle:
Short-time operation
 
KB 2 min. KB 2 min. KB 2 min. KB 2 min.
Ambient temperature +10 / +40 °C +10 / +40 °C +10 / +40 °C +10 / +40 °C
Degree of protection IP 30 IP 30 IP 30 IP 30
Type of control electrical pneumatic electrical pneumatic
Weight 7.9 - 13.5 kg 7.9 - 13.5 kg 8.6 - 17.5 kg 8.6 - 17.5 kg
Datasheet (PDF) Datasheet THC8A...    
Further Information Operating Manual Telemag    
  TELEMAG TLC12 Z...
(Voltage 230 VAC / separate switch over contact and operating elements)
Technical data TLC12ZWAS TLC12ZWAK TLC12ZWDS TLC12ZWDK
Pushforce max. 4000 N 4000 N 4000 N 4000 N
Speed 11 mm/sec. 11 mm/sec. 11 mm/sec. 11 mm/sec.
Stroke 200-700 mm 200-700 mm 255-700 mm 255-700 mm
Retracted height 375-875 mm 375-875 mm 315-760 mm 315-760 mm
Telescopic column version 2- section 2- section 3- section 3- section
Voltage 230 V/50 Hz 230 V/50 Hz 230 V/50 Hz 230 V/50 Hz
Power consumption 890 W 890 W 890 W 890 W
Current consumption 4.1 A 4.1 A 4.1 A 4.1 A
Duty cycle:
Intermittent operation
int. 1 min./
37 min.
int. 1 min./
37 min.
int. 1 min./
37 min.
int. 1 min./
37 min.
Duty cycle:
Short-time operation
 
KB 2 min. KB 2 min. KB 2 min. KB 2 min.
Ambient temperature +10 / +40 °C +10 / +40 °C +10 / +40 °C +10 / +40 °C
Degree of protection IP 30 IP 30 IP 30 IP 30
Type of control electrical pneumatic electrical pneumatic
Weight 15.2 - 24.5 kg 15.2 - 24.5 kg 18.3 - 30.5 kg 18.3 - 30.5 kg
Datasheet (PDF) Datasheet TLC12 Z...    
Further Information Operating Manual Telemag    
  TELEMAG THG.B/C...
(Voltage 24 VDC with separate control unit and operating elements)
Technical data THG1.-B THG1.-C    
Pushforce max. 2000 N 1000 N
Speed 5.5 mm/sec. 12 mm/sec.    
Stroke 200-700 mm 200-700 mm
Retracted height 2- section 470-970 mm 470-970 mm    
Retracted height 3- section 380-880 mm 380-880 mm
Voltage 24 VDC 24 VDC    
Current consumption
5 A 5 A
Duty cycle:
Intermittent operation
int. 1 min./
9 min.
int. 1 min./
9 min.
   
Duty cycle:
Short-time operation
KB 2.5 min. KB 2.5 min.
Ambient temperature +10 / +40 °C +10 / +40 °C    
Degree of protection IP 30 IP 30
Weight 8 - 14 kg 8 - 14 kg    
Design of telescopic column 2 or 3 section 2 or 3 section
Datasheet (PDF) Datasheet THG.B/C...
Further Information Operating Manual Telemag
  TELEMAG TLG.A/B/C...
(Voltage 24 VDC with separate control unit and operating elements)
Technical data TLG1.-A TLG1.-B TLG1.-C   
Pushforce max. 4000 N 2500 N 1500 N
Speed 10 mm/sec. 13 mm/sec. 25 mm/sec.    
Stroke 200-700 mm 200-700 mm 200-700 mm
Retracted height 2 section 380-880 mm 380-880 mm 380-880 mm   
Retracted height 3 section 380-880 mm 380-880 mm 380-880 mm
Voltage 24 VDC 24 VDC 24 VDC   
Current consumption 6.5 A 6.5 A 6.5 A   
Duty cycle:
Intermittent operation
int. 1 min./
9 min.
int. 1 min./
9 min.
int. 1 min./
9 min.
Duty cycle:
Short-time operation
 
KB 2.5 min. KB 2.5 min. KB 2.5 min.   
Ambient temperature +10 / +40 °C +10 / +40 °C +10 / +40 °C
Degree of protection IP 30 IP 30 IP 30   
Weight 15 - 30 kg 15 - 30 kg 15 - 30 kg  
Design of telescopic column 2 or 3 section 2 or 3 section 2 or 3 section    
Datasheet (PDF) Datasheet TLG.A/B/C...    
Further Information Operating Manual Telemag    
  TELEMAG TLT
(Voltage 24 VDC with separate control unit and operating elements)
Technical data TLT10-C1 TLT10-B1 TLT10-C2   TLT10-A1 TLT10-A2*
Pushforce max. 1000 N 2000 N 2000 N 3000 N 4000 N
Speed 25-36 mm/s 13-19 mm/s 25-42 mm/s 11-16 mm/s    13-19 mm/s
Stroke 300-700 mm 300-700 mm 300-700 mm 300-700 mm 300-700 mm
Retracted length 320-520 mm 320-520 mm 320-590 mm 320-520 mm 390-590 mm
Telescopic column version 3-section 3-section 3-section 3-section 3-section
Voltage 24 V DC 24 V DC 24 V DC 24 V DC 24 V DC
Current consumption 2x4 A 2x4 A 2x4,5 A 2x3,5 A 2x3,5 A
Duty cycle:
Intermittent operation
int. 1 min./ 9 min. int. 1 min./ 9 min. int. 1 min./ 9 min. int. 1 min./ 9 min. int. 1 min./ 9 min.
Duty cycle:
Short-time operation 
KB 2,5 min. KB 2,5 min. KB 2,5 min. KB 2,5 min. KB 2,5 min.
Ambient temperature +10 - +40°C +10 - +40°C +10 - +40°C +10 - +40°C +10 - +40°C
Degree of protection IP 40 IP 40 IP 40 IP 40 IP 40
Weight 15 - 30 kg 15 - 30 kg 15 - 30 kg 15 - 30 kg 15 - 30 kg
* A2 units have a three times static safety
factor for strokes 600 and 700 mm.
Datasheet (PDF) Datasheet TLT
Further Information Operating Manual Telemag