KOM
KOM1  KOM2  KOM3
KOM3TKOM6





KOM control units are used with different Magnetic actuators. They are available with simple relay function as well as microprocessor equipped units with parallel and memory functions. KOM units are operated with the help of electric, pneumatic or infrared control elements.
   

KOM 1
Standard-control for single operation of up to 4 actuators and with connection for 1 limit switch (optional).
  KOM 1
Technical data KOM 1
Type of control Standard
Motor connection 4
Limit switch connection (Option) 1
Voltage/current/frequency 230V / 0.8 A / 50Hz
120V / 1.6 A / 60 Hz
Power output 24VDC / 6 A
Duty cycle 1 min. ON / 9 min. OFF
Ambient temperature 0 / +40 °C
Degree of protection IP 66
Weight
(with / without accumulator)
2.7 kg / 4.0 kg
Approvals EN 60601-1
UL 2601
Datasheet (PDF) Datasheet KOM 1/2
KOM 2
Microprocessor control for various applications: Single operation of up to 5 actuators, parallel running of 2 or 2x2 actuators, Memory function with 3 positions,...)
  KOM 2
Technical data KOM 2_-_1/2 KOM 2_-_4/5
(with enhanced power)
Type of control Microprocessor Microprocessor
Motor connection 5 (4 with limit switch) 5 (4 with limit switch)
Limit switch connection (Option) 1 1
Voltage/current/frequency 230V / 0.8 A / 50Hz
120V / 1.6 A / 60Hz
230V / 2.0 A / 50Hz
120V / 3.5 A / 60Hz
Intermittent mode:    
Power output 24VDC / 6 A 24VDC / 6 A
Duty cycle 1 min. ON / 9 min. OFF 1 min. ON / 9 min. OFF
Short time operation:    
Power output - 24VDC / 12 A
Duty cycle - 3 min. ON
Ambient temperature 0 / +40 °C +10 / +40 °C
Degree of protection IP 66 IP 66
Weight
(with / without accumulator)
2.7 / 4 kg 3 kg / -
Approvals EN 60601-1
UL 2601
EN 60601-1
UL 2601-1
Datasheet (PDF) Datasheet KOM 1/2  
KOM 3/4
Compact standard or microprocessor control for the operation of up to 3 Magnetic 24VDC actuators.
  KOM 3
Technical data KOM3  
Type of control Standard  
Motor connection 3 (2 with limit switch)  
Limit switch connection (Option) 1  
Voltage/current/frequency 230V / 0.8 A / 50Hz
120V / 1.6 A / 60Hz
 
Intermittent mode:    
Power output 24VDC / 6 A  
Duty cycle 1 min. ON / 9 min. OFF  
Short time operation:    
Power output -  
Duty cycle -  
Ambient temperature 0 / +40 °C  
Degree of protection IP 66  
Weight
(with / without accumulator)
1.9 kg  
Approvals EN 60601-1
UL 2601
 
Datasheet (PDF) Datasheet KOM 3  
KOM 3T
Compact standard control with toroidal mains transformer for the operation of 1 TLT double stroke telescopic column.
  KOM 3T
Technical data KOM3T  
Type of control Standard  
Motor connection 2  
Limit switch connection (Option) 1  
Voltage/current/frequency 230V / 1.6 A / 50Hz
120V / 3.0 A / 60Hz
 
Intermittent mode:    
Power output 24VDC / 6 A  
Duty cycle 1 min. ON / 9 min. OFF  
Ambient temperature 0 / +40 °C  
Power output -  
Duty cycle -  
Degree of protection IP 66 / II  
Weight 2.2 kg  
Approvals EN 60601-1
UL 2601-1
 
Datasheet (PDF) Datasheet KOM 3T  

KOM 6
Microprocessor control for single fault safe operations in the medical sec.tor. Various applications: Single operation of up to 4 actuators, parallel running of 2 or 2x2 actuators, memory function with 3 positions,...

  KOM 6
Technical data KOM6_-_1/2 KOM6_-_4/5
Type of control Microprocessor Microprocessor
Motor connection 4 4
Limit switch connection (optional) 1 1
Voltage/current/frequency 230V / 1A / 50Hz
120V / 2A / 60Hz
230V / 2.0 A / 50Hz
120V / 3.5 A / 60Hz
Intermittent mode:    
Power output 24VDC / 6 A 24VDC / 9 A
Duty cycle 1 min. ON / 9 min. OFF 1 min. ON / 9 min. OFF
Short time operation:    
Power output - 24VDC / 12A
Duty cycle - 3 min. ON
Ambient temperature 0 / +40 °C +10 / +40 °C
Degree of protection IP 66 IP 66
Weight
(with / without accumulator)
2.7 / 4 kg 3 kg / -
Approvals EN 60601-1
UL 2601
EN 60601-1
UL 2601
-1
Datasheet (PDF) Datasheet KOM 6